The VTS Operator's Guide
Introduction to Visual Tag System (VTS)
The VTS Program and VTS Applications
Starting the VTS Program
Start the VTS Program Using the VTS Shortcut
Start the VTS Program Using the Windows Start Button
Summary: Introduction to VTS
The VTS Application Manager (VAM)
Starting a VTS Application
Stopping a VTS Application
Stopping a VTS Application Using the VAM
Stopping an Application Using the Application's Windows Close Button
Exiting VTS
Summary: The VTS Application Manager (VAM)
The Display Manager
Application Pages
Title Bar
Page Display Area
Navigation Bar
Display Manager Functions
Page Navigation Tools
Menu
Page Change Buttons
Add a Page Change Button
Remove a Page Change Button
Page History Buttons
Hotboxes
Printing a Page
Responding to an Alarm
Stopping a VTS Application Using the Application's Windows Close Button
Summary: The Display Manager
Application Security
User Accounts and Privileges
Logon to Your User Account
Change Your Password
Log Off of Your User Account
Security-related Dialogs
Access Denied: Not Logged On
Access Denied: No Privilege
Access Denied: No Application Close Privilege
Password Entries Do Not Match
Summary: Application Security
Interacting with VTS Pages
Interpreting Application Page Data
Tags
Tag Types
Tag Properties
Tag Data
Incoming Tag Data
Outgoing Tag Data
Tag Graphic Displays
Incoming Data Displays
Outgoing Data Displays
Tag Tooltips
Special Symbols
Invalid Data
Questionable Data
Interact with Pages
Mouse Behavior
Tooltips
Shortcut Menu
Disabled Shortcut Menu Options
Checkmark Shortcut Menu Symbol
Help Shortcut Menu Option
Manual Data Shortcut Menu Option
Enter Manual Data
Clear Manual Data
Questionable Data Shortcut Menu Option
Mark data as questionable
Unmark data as questionable
Disable Alarm or Alarm Disable Shortcut Menu Option
Disable an Alarm from a Application Page
Enable an Alarm from a Application Page
Alarm Setpoints Shortcut Menu Option
Deadband Shortcut Menu Option
Properties Shortcut Menu Option
Open a Windowed Historical Data Viewer Page to Instantly Plot Equipment Process Data
Summary: Interacting with VTS Application Pages
The Historical Data Viewer Page
Plotting Live and Historical Data
Historical Data Viewer Page Elements and Tools
Working with the Historical Data Viewer Page
Plot Data on the Historical Data Viewer Page
View Tag Data in a Table on the Historical Data Viewer Page
Quick-Plotting a Tag
Adding, Removing and Saving Pens
Selecting Pens in the Tag Selector
Remove a Pen or Query from the Historical Data Viewer Page
Save a Pen Group
Load a Pen Group
Modify a Pen Group
Delete a Pen Group
Filter Available Tags in the Tag Selector Dialog
Filter Tags by Name
Filter Tags by Area
Filter Tags by Description
Filter Tags by Their Data Source Type
Filter Tags by Tag Type
Use a Query to Select Tags
Preview the Expanded Tag List
Modifying Pen Properties
Modify Analog Pen Properties
Modify Digital Pen Properties
Modify Notebook and Note Properties
Modifying Dates and Times
Select a Date Upon Which to View Logged Data on the Historical Data Viewer Page
Modify the Time Duration for the Data Plotted on the Historical Data Viewer Page
Zoom In to View Lesser Time Periods on the Graph
Zoom Out to View Greater Time Periods on the Graph
Scroll to View Earlier or Later Dates
Reset the Graph to the Current Date
Modifying Scale Ranges
Zoom In to View a Lesser Scale Range for One Analog Pen
Zoom In to View a Lesser Scale Range for All Analog Pens
Zoom Out to View a Greater Scale Range for One Analog Pen
Zoom Out to View a Greater Scale Range for All Analog Pens
Shift One Analog's Scale Range on the Graph
Shift All Analogs' Scale Range on the Graph
Reset One Analog to its Original Scale Range
Reset All Analogs to Their Original Scale Range
Working with Notebooks
Add a Note to a Notebook
Add a Note on the Graph
Add a Note to the Table
Summary: The Historical Data Viewer Page
The Alarm Page and Alarms
Features of the Alarm Page
Alarms and Events
Alarm Page Components
List Options Buttons
Actions Buttons
Alarm List Font Size Control Panel
Sorting and Filtering Drop-Down Lists
Alarm List Columns
Alarm List
Alarm Page Operations
Alarm Indicators
Responding to Alarms
Analyzing the Alarms in the Alarm List
Acknowledge One Alarm
Acknowledge All Alarms
Silence the Current Alarm Sound
Mute Current and Future Alarm Sounds
Change the Alarm List Font Size
Changing the Category of Alarms Displayed in the Alarm List
View Active Alarms
View Configured Alarms
View Current Alarms
View Disabled Alarms
View History Alarms and Events
View Unacknowledged Alarms
Disabling and Enabling Alarms from the Alarm Page
Disable Alarms from the Alarm Page
Enable Alarms from the Alarm Page
Sorting the Alarms in the Alarm List
Sort the Alarm List by Date and Time
Sort the Alarm List by Priority
Sort the Configured List by Alarm Name
Filtering the Alarms in the Alarm List
Apply a Priority Filter to the Currently Displayed Alarm List
Apply an Area Filter to the Currently Displayed Alarm List
Remove a Priority Filter from the Alarm List
Remove an Area Filter from the Alarm List
Resize the Alarm List Columns
Printing the Alarm List
Print the Alarm List to the Default Windows Printer
Print the Alarm List to File
Summary: The Alarm Page and Alarms
The Reports Page
Report Types
Daily Snapshot Report
Daily Total Report
Driver Communication Error Detail Report
Driver Communication Summary Report
Hourly Snapshot Report
Hourly Total Report
Standard Report
Saving and Loading Tag Groups
Save a Tag Group
Load a Tag Group
Report Time Periods
Select a Preset Time Period for a Report
Configure a Custom Time Period for a Report
Generate Multiple Reports Simultaneously
Report Output Formats
Default Printer Report Output Format
Printer Report Output Format
Text File Report Output Format
Screen Display Report Output Format
CSV File Report Output Format
Formatted Excel XLS File Report Output Format
Plain Excel XLS File Report Output Format
Access MDB File Report Output Format
ODBC Data Source Report Output Format
Send Report Data By E-mail
Send Report Data in the Body of an E-mail Message
Send Report Data as Attachment to an E-mail Message
Generate a Report
The Operator Notes Page
Add a Note to the Operator Notes Page
Print the Notes Displayed on the Operator Notes Page
View Operator Notes Entered on Previous Dates
View Operator Notes Entered on Subsequent Dates
The Call-out List Page
Activate a Roster for the Alarm Dialer System
Disable the Alarm Dialer System
Managing Contact Records for the Alarm Dialer System
Modify an Operator's Contact Information for the Alarm Dialer System
Add Contact Information for a New Operator to the Alarm Dialer System
Delete Contact Information for an Operator from the Alarm Dialer System
Change the Order of Operator Contact Records for the Alarm Dialer System