Device Driver List

Use the Devices You Choose: The device drivers listed below allow VTScada to communicate with over a hundred industry standard monitoring and control products. Contact us if you don’t see the device driver you need. We can create a driver to suit virtually any need you may have. *

Connectivity Partners: Trihedral also works closely with third-party OEMs to improve the experience of our shared customers. See VTScada Connectivity Partners.

Our device drivers fall into one of three categories:

Level 1 – Maintained and tested by Trihedral. Integrated with VTScada and ships with all systems.
Level 2 – Tested by Trihedral. VTScada support at time of testing. Available from us as a plug-in.
Level 3 – Script-only driver. Integration with Visual Tag System Driver Template required.

 

Multi-vendor Protocols:

VTScada communicates with many devices using industry standard communication protocols.

Download the Device Driver List (PDF) Updated: February 13, 2017

Protocol

Devices

Medium

Additional Information

1

2

3

BACnet

BACnet Compliant Devices

Serial RS-485, BACnet/IP

BACnet

X

DDE (Dynamic Data Exchange)

DDE Compliant Software

DDE Client

X

DNP 3.0

DNP 3.0 Compliant Devices

Serial, Ethernet

X

Enron Modbus®

Enron Modbus Compliant Devices

Serial, TCP/IP

Enron Modbus

X

JSON

JSON Compliant Devices

TCP/IP

Also support XML.

X

Modbus ASCII, Modbus TCP/IP
Modbus UDP/IP, Open Modbus TCP, Modbus PLUS, Modbus RTU

Modbus Compliant Devices

Serial, Ethernet, TCP, Ethernet UDP, Modbus Plus

Modbus PLUS requires additional hardware

X

OPC® Client

OPC Servers for various Products

Serial, Ethernet

Supports hundreds of 3rd party OPC servers

X

Simple Network Management Protocol (SNMP)®

Standardized protocol for thousands of devices

Ethernet

X

SNMP Agent

Allows VTScada to supply data like a network device

Ethernet

X

SQL Data Query (ODBC)

SQL Databases

ODBC

X

Device-Specific Protocols

Organization

Devices

Medium

Protocol

Additional Components

1

2

3

ABB®

Variable Speed AC Drive

Serial

Modbus

X

Acromag®

Ethernet I/O Modules

Ethernet

Modbus TCP/IP

X

Allen-Bradley® / Rockwell Automation®

Enhanced CIP:
As of 11.2, CIP is faster, requires less bandwidth, and is easier to
configure thanks to a built-in PLC tag browser.

PLC-2

Serial

DF1

AB Serial Interface Module

X

PLC-3

DH+

DF1

Woodhead 5136-SD (ISA or PCI)

X

Serial

DF1

X

PLC-5

Serial

DF1

X

DH+

DF1

Woodhead 5136-SD (ISA or PCI)

X

Ethernet

DF1

PLC-5E only

X

SLC500 (all processors)

Serial

DF1

X

DH+

DF1

Woodhead 5136-SD (ISA or PCI)

X

Ethernet

DF1

X

MicroLogix™

Serial

DF1

X

RS-485/RS-232 Serial

Modbus RTU

X

Ethernet

DF1, CIP

X

CompactLogix® and ControlLogix®

Serial

DF1

X

Ethernet

DF1, CIP

X

SoftLogix5800™

Ethernet

CIP

X

Aquatrol®

1300 RTU

Serial

Aquatrol

Special communication hardware

X

1500 RTU

Serial

Aquatrol

X

Bailey®

Network 90 DCS

Serial

Bailey

Bailey CIU

X

Bristol Babcock®

33xx family and ControlWave

Serial

BSAP

X

Ethernet

IBP

X

Campbell Scientific®

CR10X and CR510 Data Loggers

Serial

Array Based OS

X

CR200, CR800, CR850, CR1000, CR3000, CR5000 Data Loggers

Serial, TCP/IP

Pakbus OS

X

Control Microsystems®

Telesafe Micro® 16 RTU

Serial

Modbus RTU, Modbus ASCII, DF1, DNP

DF1 & DNP are Telesafe options

X

SCADAPack® RTU Family

Serial, Ethernet

Modbus RTU, Modbus ASCII, Modbus TCP/IP & UDP/IP, Open Modbus
TCP, DNP3 Datalogging and Store & Forward Supported

X

RealFLO®

Serial, Ethernet

Enron Modbus

X

CSE Semaphore

TBox® RTU

Serial, TCPIP

Modbus, Open Modbus/TCP

X

TFlo® (TBox RTU)

Serial, TCPIP

Enron Modbus, Enron via Open Modbus/TCP

X

TBox RTU Sample Tables, TBox RTU Chronologies

Serial, TCPIP

Modbus, Open Modbus/TCP

X

DAQ

Serial

DNP 3.0

X

Data Flow Systems®

RTU

Serial, Ethernet (TCP /IP& UDP/IP)

Data Flow Systems

Includes TACII, HyperTAC, HyperServer Database Conversions

X

Dexter Fortson®

DFA A-RTU

Serial, Ethernet

Openlink

X

Digital Control Company (DCC) ®

DCC Pump Controllers

Serial (RS232)

Modbus ASCII

X

Federal Pioneer®

DSM-2P Power Meters

Serial

Federal Pioneer

X

Fisher®

ROC800, 800L, FloBoss™ 103, 107 (supports other ROC devices)

Serial, TCP/IP

ROC, ROC Plus

X

Foxboro®

731C Loop Controller

Serial

Foxboro

X

743C Loop Controller

Serial

Foxboro

X

761C Loop Controller

Serial

Foxboro

X

C50 RTU

Serial

DNP 3.0

X

General Electric®

Series 1 PLC, Series 5 PLC, Series 6 PLC

Serial

General Electric

X

Series 90 PLC

Serial

SNP, SNPX

X

Series 90 PLC

Ethernet

SRTP

X

RX3i PLC

Ethernet

SRTP

X

Granville Phillips®

307 Vacuum Controller

Serial

Granville Phillips

X

Hewlett-Packard®

HP48000 RTU

Serial

Subset, HEX-ASCII

X

IDEC®

Micro CP12

Serial

IDEC

X

Micro CP13

Serial

IDEC

X

Micro FA2

Serial

IDEC

X

Micro FA3

Serial

IDEC

X

Landis & Gyr®

Telegyr 8979

Serial

Landis & Gyr

X

Lantronix®

UDS-10, UDS-100 Serial to Ethernet Converters

Serial/Ethernet

Most Serial Protocols

X

Mitsubishi®

A Series

Serial

Mitsubishi

X

Moore®

APACS ACM 040-4M

Moore

Moore

Requires Moore interface card for PC

X

Motorola®

Moscad RTU Family, ACE Family

Serial, Ethernet

DDE, Modbus

X

Ethernet

Motorola IP Gateway API

MDLC IP Gateway

X

MPE®

MPE Duplex Controller

Serial, Ethernet

Modbus

X

MultiTrode®

MultiTrode Pump Controller®

Serial, Ethernet

Modbus, DNP 3.0

X

NMEA

NMEA Compliant Devices

Serial

NMEA 0183

X

OSI Soft®

PI Database (Read Only)

API

API

Requires PI Client Software

X

Omron®

C-series Programmable Controllers

Serial

Hostlink

X

CS Series PLCs

Serial

Hostlink

X

CJ Series PLCs

Serial

Hostlink

X

CS and CJ PLCs

Serial, Ethernet

FINS

X

Opto 22®

Optomux

Serial

Optomux

X

PLC Direct® (Koyo®)

DL family of PLCs

Serial

Direct Net

X

Ethernet

OPC Client (K Sequence)

OPC Server from Kepware

X

Open Modbus/TCP

X

Power Measurement Ltd.®

ION Series Meters

Serial, Ethernet

Modbus, DNP 3.0

X

Powers Process Controllers®

330, 350, 512, 535, 545

Serial

Powers

X

Quindar®

SCADA Master

Serial, Ethernet (TCP/IP & DECNet)

QNet

X

Schlumberger®

Q1000 meter

Serial

DNP 3.0

X

Siemens®

S5 Series PLC

X

SIMATIC TI 305, 405 Series PLCs

Serial

Direct Net

X

S7-200 Series PLC

Ethernet

OP/PG

Requires Siemens Ethernet Communications Processor

X

OPC over Serial, OPC over Ethernet

OPC Client

Requires OPC Server

X

S7-300 Series PLC

Ethernet

OP/PG

May Require Siemens Ethernet Communications Processor

X

OPC over Serial, OPC over Ethernet

OPC Client

Requires OPC Server

X

S7-400 Series PLC

Ethernet

OP/PG

Requires Siemens Ethernet Communications Processor

X

OPC over Serial, OPC over Ethernet

OPC Client

Requires OPC Server

X

Sierra Misco®

See Stevens Water

Sixnet®

Micro-Versa TRAC

Ethernet

Modbus, TCP/IP

X

Sixnet SixTRAC

Serial

Modbus, RTU/ASCII

X

Square D®

Sy/Max PLCs

Serial

Square D

X

Stevens Water®

SM0850

Serial

Stevens

X

Surfline®

9009, 9015 Series

Serial

Surfline

Requires Surfline CP Module

X

Texas Instruments®

TI 305, 405 Series PLCs

Serial

Direct Net

X

Toshiba®

T2, T2E PLCs

Serial

Toshiba

X

Woodward®

easYgen Series

Serial

Modbus RTU

X

EGCP-3

Serial

Modbus RTU

X

DTSC

Serial

Modbus RTU

X

DLSC-2

Ethernet

Modbus TCP

X

723 PLUS

Serial

Modbus RTU

X

733

Serial

Modbus RTU

X

828

Serial

Modbus RTU

X

Zetron®

1708, 1716, 1730, 1732

Serial

Modbus

Requires Modbus Chip

X

* Note:

  • Some of the drivers above are not included in the base price of VTScada software licenses.
  • Some of the drivers above require integration and are not available ‘out-of-the-box’ with VTScada software licenses.
  • Prices for new driver development are determined on a case-by-case basis.
  • This list may change without notice.